VT855t Big Data Center Monitoring Unit

€688.80
Tax included

Description

The VT855 / Big Data Center Monitoring Unit can be used for remote environmental monitoring in big data centers. Its primary features include:

  • Environmental Monitoring: Measures temperature, humidity, voltage, access, smoke, dust, vibration, access, leakage, movement, airflow.

  • I/O Controller: 8 analog inputs, 2 CAN inputs, 32 dry contacts IN and 8 OUT, 4 relays, SD, USB, extensions.

  • Scalability: Supports up to 1500 elements, including sensors, virtual sensors, logic, notifications.

  • Built-in Web Interface: 100Mbit/s.

  • Extensions: LTE modem, Modbus, Reader.

  • Notifications: Telegram, push, mail; VPN, SMS and voice call in case of LTE modem built-IN.
  • Processor: 1Ghz dual-core Cortex-A7,  128Mbit RAM.

Specification

Device type:
Monitoring unit
Network Interface:
100Mit/s
Analog ports:
8
CAN:
2
Max. distance from the unit:
Analog sensors: 50-150m, CAN - 225m
Maximum units in a CAN bus:
31, depends on CAN device type
Relays with output 12V:
2
Power relays:
2
Dry contacts IN:
32
Dry contacts OUT:
8
Mounting:
19"
Extensions:
SD, USB-C
Expansions:
4G, RS485
Built-In:
Rechargeable board, battery board
Status Indicators:
Red (Error), Green Led, Yellow, Orange (Relais)
Processor:
Dual core ARM, 1 Ghz, 128 MB
Power inputs:
230VAC, 24-48V DC
Operating temperature:
-10° C to +80° C
Origin of goods:
Made in EU
HS Code:
8537 10 910

Use cases

The VT825t is a powerful device that takes your data center operations to the next level.

  • The VT855t provides advanced protection against data loss. It continuously monitors environmental conditions to ensure optimal server operation.
  • Remote monitoring and control: A single interface for multiple sensors ensures that no critical event goes unnoticed.

VT855 versions

VT855 unit provides power backup capability.

VT855t :
230 VAC power input.
VT855tt :
Two 230 VAC power inputs provide backup power.
VT855DC :
24-48V DC power input.
VT855DCDC :
Two 24-48V DC power inputs providing a redundant power supply.
VT855tDC :
230V AC power and 24-48V DC power inputs. Redundancy supported.

Extensions

VT7670 LTE slot modem

Allows to receive and send SMS notifications (2G, 3G). Provides Ethernet reservation over LTE (4G).

Extension slot

VT485r Reader extension

Allows to connect readers, and keypads with OSDP protocol support.

or

VT485m Modbus extension

Allows to monitor up to 32 Modbus RTU devices/meters/sensors.

Battery slot

VT-ACCU Rechargeable backup battery

Keeps the device operational while the main power source drops.The device uses two 3.7V rechargeable lithium batteries 14500. If the main power input voltage drops, the unit will work from VT-ACCU rechargeable batteries until the batteries are discharged.

or

VT-BAT Backup battery 9V

Keeps the device operational while the main power source is disabled. The device uses a non-rechargeable 6F22 9V lithium battery.

Advanced protocols

Vutlan supports most popular communication protocols & adding more...

SNMP v1, v2c, v3

Simple Network Protocol for connecting multiple Vutlan units to a single DCIM, NMS, and Infrastructure monitoring software.

+

Modbus RTU,
Modbus TCP

Modbus serial communication protocol designed for industrial automation systems, and industrial meters.

+

OSDPv2 RS485

Open Supervised Device Protocol is an access control communications standard for readers, & keypads.

+

and other...

DHCP, HTTP, HTTPS, SMTP, FTP, Syslog, TLS, DynDNS, RADIUS, SSL, NTP, OpenVPN

Built-in web interface

All Vutlan monitoring devices have a built-in multilingual web interface for monitoring and managing the device.

Here you can configure notifications and alerts, logic schemes, user access rights, sensors and elements.

You can also view sensor graphs, logs and camera images.

Add more analog sensors using VT408 extension unit.

Each VT408 extension unit connected to the Vutlan monitoring device via the CAN bus adds the ability to connect 8 analog sensors to the system.

Sensors connected to the unit are automatically displayed in the system.

Add more Dry contacts using VT440

The VT440 / Dry Contacts extension unit increases the number of Dry contacts that can be connected to any Vutlan monitoring device.

Each VT440 device adds 32 dry contacts. Each VT440 + VT32 expansion module adds 64 dry contacts. 

A tab for monitoring and configuring dry contacts is available in the Vutlan device interface.

Connecting CAN sensors

You can connect multiple CAN devices to a CAN bus chain.

Each VT408 unit in the CAN bus chain adds 8 analog sensors. Each VT440 unit adds 32 or 64 dry contact inputs to the system.

An additional CAN12V-1A power supply is only required if the number of CAN devices in the CAN bus chain exceeds 12 pieces.